Trimble Nomad
Nomad Configurations:
Standard Features | |
Windows Mobile 6.1 | Integrated speaker and microphone |
Sunlight readable color TFT display | 15 hours of continuous room temperature operation with default settings |
Touchscreen | Optional integrated Bluetooth and 802.11g wireless capability |
Rugged waterproof design | |
Electrical | |
Processor | Marvell PXA320 XSCALE 806 MHz |
Memory | 128 MB DDR SRAM |
Storage | 512 MB to 2G onboard non-volatile NAND Flash |
Expansion | 1x SD/SDHC slot |
Display | 480 X 640 pixel(VGA) color TFT with LED front light |
Batteries | 5200 mAh Li-ion rechargeable module |
I/O | USB host and client, power, headset jack |
Physical | |
Size | 6.92 in x 3.92 in x 1.96 in (17.6 cm x 10 cm x 5 cm) |
Weight | 21 ounces (596 g) including rechargeable batteries |
Housing | Polycarbonate |
Environmental Specifications | |
Water | Immersed in 1 meter of water for 30 minutes Water Jet 12.5 mm dia. @ 2.5 m–3 m, 100 Liter/min MIL-STD-810F, Method 512.4, Procedure I IEC-529, IP67 |
Sand and dust | 8 hours of operation with blowing talcum powder MIL-STD-810F, Method 510.3, Procedures I, II IEC-529, IP67 |
Drop | 26 drops at room temperature from 4 ft (1.22 m) onto plywood over concrete 6 additional drops at –22 °F (–30 °C) 6 additional drops at 140 °F (60 °C) MIL-STD-810F, Method 516.5, Procedure IV |
Vibration | General Minimum Integrity and Loose Cargo test MIL-STD 810F, Method 514.5, Procedure I, II |
Operating Temperature | –22 °F to 140 °F (–30 °C to 60 °C) MIL-STD 810F, Method 501.4, Procedure II MIL-STD 810F, Method 502.4, Procedure I, II, III |
Temperature shock | –22 °F/149 °F (–35 °C/+65 °C) MIL-STD-810F, Method 503.4, Procedure I |
Humidity | 90%RH temp cycle 32 °F/158 °F (0 °C/+70 °C) MIL-STD-810F, Method 507.4 |
Altitude | 15,000 ft at 73 °F (5 °C) and 40,000 ft at –22 °F (–30 °C) MIL-STD-810F, Method 500.4, Procedures I, II, III |